
COMPLETE GENERATOR REPAIR AND ENGINE OVERHAUL FACILITY
GENERATOR REPAIR SERVICES
DIESEL ENGINE OVERHAUL AND REPAIR, MOTOR REWINDING, LOAD TESTING, OIL CHANGE, FUEL PUMP REPAIR & CALIBRATION FACILITIES

DIESEL ENGINE REPAIR AND REBUILDING FACILITY
PRECISION ENGINE REBUILDING FOR UNMATCHED POWER
IN-DEPTH ENGINE DIAGNOSIS, COMPONENT RESURFACING, CRANKSHAFT MACHINING, AND COMPLETE REASSEMBLY TO RESTORE DIESEL ENGINE FUNCTIONALITY.

GENERATOR & ALTERNATOR REWINDING FACILITY
HIGH-PRECISION STATOR & ROTOR REWINDING FOR MAXIMUM OUTPUT

GENERATOR OIL CHANGE
EXTEND ENGINE LIFE WITH EXPERT LUBRICATION & MAINTENANCE
COMPREHENSIVE ENGINE OIL CHANGE, FILTER REPLACEMENT, BELT & HOSE CHECKS, AND COOLING SYSTEM SERVICING TO ENSURE SMOOTH OPERATION.

GENERATOR LOAD TESTING FACILITY
SIMULATED LOAD TESTING TO GUARANTEE PERFORMANCE UNDER STRESS

CATERPILLAR, CUMMINS, PERKINS, ONAN GENERATOR REPAIR
EXPERT REPAIRS FOR LEADING DIESEL GENERATOR BRANDS
DIAGNOSIS, FAULT RECTIFICATION, AND PARTS REPLACEMENT USING GENUINE SPARES TO ENSURE PEAK PERFORMANCE FOR ALL MAJOR BRANDS.

FUEL PUMP REPAIR AND CALIBRATION SERVICES
HIGH-PRECISION FUEL SYSTEM TUNING FOR MAXIMUM EFFICIENCY
REPAIR, FLOW TESTING, AND CALIBRATION OF FUEL PUMPS AND INJECTORS TO ENSURE OPTIMAL COMBUSTION, REDUCE FUEL WASTE, AND ENHANCE ENGINE PERFORMANCE.

.jpg)
PERKINS
.jpg)
KOHLER
OUR EXPERIENCE IN GENERATOR REPAIRS
ABRA DIESEL GENERATOR REPAIRING TEAM IS A SPECIALIST IN GENERATOR REPAIR AND SERVICING. OUR HIGHLY SKILLED TEAM CAN DIAGNOSE AND FIX ANY ISSUE RELATED TO DIESEL GENERATORS WITH PRECISION AND EFFICIENCY.
WITH YEARS OF EXPERIENCE, WE DELIVER PROFESSIONAL REPAIRS AND MAINTENANCE TO ENSURE UNINTERRUPTED POWER SUPPLY. AS THE LEADING GENERATOR REPAIR COMPANY IN THE UAE, WE TAKE PRIDE IN OUR EXCELLENCE AND RELIABILITY.
WE SERVICE AND REPAIR ALL MAJOR DIESEL GENERATOR BRANDS, INCLUDING CUMMINS, PERKINS, CATERPILLAR, ONAN, FG WILSON, AND MORE. OUR TEAM SPECIALIZES IN COMPLETE OVERHAULS, DIAGNOSIS, AND ROUTINE MAINTENANCE TO KEEP YOUR GENERATOR RUNNING SMOOTHLY.
WHETHER IT’S INDUSTRIAL OR COMMERCIAL GENERATORS, WE PROVIDE EXPERT SOLUTIONS TO ENSURE OPTIMAL PERFORMANCE AND LONGEVITY. TRUST ABRA DIESEL GENERATOR REPAIRING FOR UNMATCHED SERVICE AND RELIABILITY!

CATERPILLAR

CUMMINS
.jpg)
FG WILSON

VOLVO PENTA

EMERGENCY BREAKDOWN REPAIR SERVICES
24/7 RAPID RESPONSE
OUR EXPERT TECHNICIANS ARE READY ROUND-THE-CLOCK TO DIAGNOSE AND FIX GENERATOR FAILURES, ENSURING MINIMAL DOWNTIME.

CONTROL PANEL DIAGNOSIS & REPAIR
ADVANCED TROUBLESHOOTING FOR GENERATOR CONTROL PANELS
WE REPAIR AND RECALIBRATE FAULTY GENERATOR CONTROL PANELS, ENSURING PROPER SYNCHRONIZATION, LOAD BALANCING, AND AUTOMATED SWITCHING.

IN HOUSE MACHINE SHOP SERVICES
SURFACING, GRINDING, POLISHING SERVICES FOR CYLINDER HEAD, CONN ROD, ENGINE BLOCK AND CRANKSHAFT

HONING, BORING, GRINDING, POLISHING AND REFACING SERVICES
PRECISION SERVICES LIKE HONING, BORING, GRINDING, POLISHING, AND REFACING ARE ESSENTIAL TO RESTORE ENGINE COMPONENTS TO THEIR ORIGINAL SPECIFICATIONS. THEY ENSURE SMOOTH OPERATION, OPTIMAL COMPRESSION, REDUCED WEAR, AND EXTENDED ENGINE LIFE BY ELIMINATING IMPERFECTIONS AND ENHANCING PERFORMANCE
-
HOW OFTEN SHOULD OIL CHANGE BE DONE IN A DIESEL ENGINE?Oil changes should be done every 250 hours of operation or as recommended by the manufacturer. Regular oil changes ensure proper lubrication, prevent wear and tear, and extend engine life. For generators under heavy load or harsh conditions, more frequent changes may be required.
-
IS EMERGENCY GENERATOR REPAIR POSSIBLE?Yes, emergency generator repair is possible, and we offer 24/7 urgent repair services to get your generator running as quickly as possible. Whether it's a sudden breakdown, power failure, or component malfunction, our expert technicians are ready to diagnose and repair your generator on-site.
-
WHAT ARE THE CAUSES OF WHITE SMOKE IN A DIESEL ENGINE?White smoke in a diesel engine is usually caused by incomplete combustion due to: Low engine temperature (cold start) Faulty injectors or incorrect fuel timing Water or coolant mixing with fuel (blown head gasket, cracked cylinder head) Low compression due to worn-out piston rings or valves Ignoring this issue can cause serious engine damage, so it should be diagnosed and repaired immediately.
-
WHAT ARE THE COMMON PROBLEMS OF A GENERATOR?The most common generator problems include: Battery failure – Weak or dead battery preventing startup Fuel system issues – Clogged filters, air in fuel lines, or fuel contamination Overheating – Low coolant levels or radiator blockages Alternator failure – Worn-out brushes or damaged windings Control panel faults – Sensor failures or wiring issues Regular maintenance and timely servicing can prevent these problems and keep your generator in peak condition.
-
WHY WON’T MY GENERATOR START?A generator may fail to start due to: Dead or weak battery Faulty fuel pump or clogged fuel filters Low oil pressure or coolant levels triggering safety shutdown Worn-out starter motor Damaged glow plugs or injectors (for diesel generators) Checking these components and regularly servicing your generator can help prevent startup failures.
-
HOW TO SOLVE A DIESEL ENGINE LOCKED OUT ISSUE?A diesel engine lockout (engine refusing to start due to safety shutdown) can be caused by: Low oil pressure or high temperature shutdown – Check and refill fluids Emergency stop engaged – Reset the emergency stop button Fuel starvation – Bleed air from the fuel system Mechanical seizure – If the engine is completely locked up, it may need professional disassembly and repair If your diesel engine remains locked out, contact us for expert troubleshooting.
-
HOW TO REPAIR A GENERATOR CONTROL PANEL?Generator control panel issues can be caused by: Faulty sensors or wiring connections Software or programming errors Display screen failure or keypad malfunction Damaged relays, circuit boards, or power modules Our team specializes in control panel diagnostics, wiring repairs, software updates, and module replacementsto restore full generator functionality.
-
WHERE DO YOU OFFER SERVICES?We are based in Sharjah and provide diesel generator repair and diesel engine rebuilding services across the UAE, including Dubai, Ajman, Ras Al Khaimah, Fujairah, and Umm Al Quwain.
WELCOME TO ABRA DIESEL

WE ARE DIESEL REPAIR EXPERTS IN THE UAE SINCE 2011
WITH DECADES OF EXPERIENCE IN DIESEL ENGINES. WE OFFER CYLINDER HEAD MACHINING FACILITY, ENGINE BORING FACILITY, FUEL PUMP CALIBRATION FACILITY, CRANKSHAFT REPAIRING FACILITY, CONNECTING ROD REPAIRING FACILITY, ENGINE HONING FACILITY, TURNING MACHINE FACILITIES, HYDRAULIC PRESS FACILITY, TURBO REPAIRING FACILITY, FUEL INJECTOR MARINE AND INDUSTRIAL CALIBRATION FACILITY, COMPLETE ENGINE OVERHAULING FACILITY, GENERATOR REWINDING FACILITY, AND CONTROL PANEL REPAIRING FACILITY FOR DIESEL ENGINES, GENERATORS, PROPELLORS, TRUCK ENGINES, FIRE PUMP ENGINES, AIR COMPRESSORS, HEAVY-DUTY EQUIPMENT ENGINES, MARINE ENGINES, AND BOAT ENGINES. WE HAVE EXTENSIVE SERVICE EXPERIENCE WITH MAJOR COMPANIES ACROSS THE U.A.E. AND INTERNATIONALLY. WITH OUR NEWLY INTRODUCED STATE-OF-THE-ART MACHINE SHOP FACILITY, WE HAVE FURTHER ENHANCED OUR SERVICE CAPABILITIES.OUR DEDICATED AND EXPERIENCED TECHNICAL TEAM WARMLY INVITES YOU TO EXPERIENCE OUR NEW FACILITIES AND SERVICES.
EMIRATES INTERNATIONAL ACCREDITATION CENTRE (EIAC) CERTIFIED (ISO 9001:2015)
KEY PERSON IS ALWAYS ACTIVE IN WORKSHOP AND 24 / 7 DIRECTLY ANSWERING CLIENT.
COST EFFECTIVE, HIGH QUALITY AND TRUSTED DIESEL REPAIR SERVICE
COMPLETE IN HOUSE CALIBRATION, REPAIR AND MACHINING FACILITES
-
ENGINE OVERHAULING & SERVICE
-
MACHINE SHOP ( CYLINDER HEAD, ENGINE BLOCK, CONNECTING ROD, CRANKSHAFT )
-
GENERATOR OVERHAULING AND SERVICE
-
FIRE PUMP/ ENGINE SERVICE & REPAIR
-
ELECTRICAL MOTOR SERVICING & REWINDING
-
FUEL PUMP AND MARINE FUEL PUMP REPAIRING & SERVICING
-
GOVERNOR REPAIR AND CALIBRATION
-
FUEL INJECTOR SERVICING & CALIBRATION
-
TURBO SERVICING & CALIBRATION
-
ALTERNATOR SERVICING & CALIBRATION
-
COOLER SERVICING & REPAIRING
-
STARTER MOTOR REPAIR (ELE & AIR)
-
SPARE PARTS SUPPLY
![]() |
---|
![]() |
![]() |
![]() |



